586-405-0227
Landmark Electric, Inc.

Electrical Panels & Service Upgrades

Subpanel Installation

A subpanel adds circuit-distribution space; it does not create unlimited electrical capacity. Landmark Electric sizes the feeder, verifies the supplying panel and service, plans neutral-ground separation and coordinates the new panel with the loads it will serve.

Services available within subpanel installation

Subpanel Installation includes a defined group of related evaluation, repair, installation and coordination services. Landmark selects only the services supported by the property, equipment and approved project objective.

The written option identifies which services apply, what Landmark supplies, known access limits and any customer, utility, manufacturer or other-trade responsibility before work moves forward.

  • Feeder sizing.
  • Neutral-ground separation.
  • Working clearance.
  • Circuit capacity.
  • Detached-building coordination.
  • Subpanel Installation evaluation and project-fit review.
  • Existing electrical panels & service upgrades system and capacity review.
  • Repair, correction or replacement options based on field findings.
  • Code, equipment-listing and manufacturer-instruction review for the approved scope.

Flexible payment options

Plan a panel or service upgrade with financing in view.

Landmark works with independent finance companies to offer qualified customers a range of payment-plan options. Review the available providers and continue through the provider you choose.

What a subpanel can solve

A subpanel can organize circuits near an addition, basement, workshop or equipment area, provide additional breaker spaces, or support a renovation with a defined feeder. It does not increase the utility service rating and should not be used to bypass an overloaded or unsuitable main panel.

Landmark reviews the proposed loads, feeder path, source-panel capacity and physical location before sizing or pricing the installation.

Core installation decisions

The feeder conductors and overcurrent protection are selected for the permitted load and wiring method. Downstream neutral and equipment-ground paths are kept properly separated, and the enclosure, working space, labeling and circuit protection are coordinated with the environment and use.

  • Feeder rating, conductor type, route and physical protection
  • Main-panel and service capacity for the proposed loads
  • Panel location, access, working clearance and environmental rating
  • Neutral isolation, equipment grounding and bonding
  • Circuit directory, required surge or fault protection and permit inspection

Detached buildings need a broader project plan

A panel in a detached garage or outbuilding can also involve underground wiring, trenching, grounding electrodes, disconnecting means and building-specific requirements. Those projects are planned under Detached Garage & Outbuilding Power so the feeder, building and end uses remain one coordinated scope.

Codes and standards that apply

These references explain the framework for this work. The adopted code, Michigan amendments, local authority, utility rules, equipment listings and manufacturer instructions must be considered together for the actual installation.

Technical content last reviewed August 3, 2026. Requirements may change; project-specific determinations are made from the adopted rules and field conditions.

Frequently asked questions

Will adding a subpanel increase my home's amperage?

No. It adds distribution capacity and breaker spaces, but the service and supplying feeder still limit the available electrical capacity.

Can a subpanel be installed anywhere?

No. The location must satisfy access, working-space, environmental and occupancy restrictions. The feeder route and the equipment being served also affect the choice.

Why are neutral and ground separated in a subpanel?

Downstream separation helps keep normal neutral return current off equipment-grounding paths and bonded metal parts. The service and feeder arrangement determine the correct connection points.

Technical review

Reviewed by Landmark Electric

This service information was reviewed for scope, safety context and accuracy by Landmark Electric, Inc., Michigan Electrical Contractor License #6114673. It provides general planning information; the adopted rules, local authority, utility requirements, equipment instructions and actual field conditions control each project.

Last reviewed: August 3, 2026Verify a Michigan license

What your service visit includes

Your $79 dispatch and evaluation charge covers sending an electrical professional to your property and the initial on-site evaluation. During that evaluation, the electrician examines the relevant accessible system, shows or explains the supported findings and identifies the cause when the available evidence reasonably allows. Clear, flat-rate options are presented before approved work begins, and the charge is waived when you proceed with approved work during the visit. Any special access, extended diagnosis, permit or after-hours considerations are explained before work moves forward.

Local. Licensed. Ready.

Clear electrical options start with a careful evaluation.

Book OnlineRequest serviceCall 586-405-0227